UK company offering Local exhaust ventilation LEV testing

Of the five controls tested the enclosing hood, the downdraught bench and the on-tip extraction system are the most effective. Each has advantages and disadvantages in various situations and careful consideration of the processes and tasks to be controlled is required to select between the three. The mobile capturing hood is capable of controlling exposure if used correctly, but like all capturing hoods requires repositioning if the source moves in order to keep it within the effective capturing zone. This means that the potential for worker misuse leading to exposure to solder fume is high, for this reason it should be considered secondary to the other forms of control in the opinion of the author.

“Every employer who provides any LEV to meet regulation 7 shall ensure that, it is maintained in an efficient state, in efficient working order, in good repair and in a clean condition – Regulation 9.1 COSHH” Where engineered controls have been used the employer must ensure that they are tested and thoroughly examined with a suitable record kept for minimum of 5 years. Further more the regulation states that: “Any LEV system must be thoroughly appraised and tested at least once every 14 months. – Regulation 9.2. This is reduced to 6 months in certain circumstances.”

As LEV is a control measure under COSHH Regulations it must be regularly and thoroughly inspected and tested. As stated above, LEV regulations outline that any employer who uses local exhaust ventilation to control hazardous substances must ensure that it is operating effectively. Local Exhaust Ventilation Testing is a legal requirement in the UK. All equipment must be thoroughly examined and tested by a competent person at least every 14 months to ensure employees are safe.

All Companies and Employers using extraction equipment have legal requirements they must undertake. All equipment must be examined and tested in order to comply with Regulation 9 of the COSHH Regulations. The Employer must make sure that equipment is maintained and in efficient working order and of good repair. A thorough test should be undertaken once every 14 months and in some cases far more frequently. It is also a requirement of the employer to keep a suitable record of the test. All for a period of at least 5 years. This record should also include details of repairs carried out as a result of the test. See extra info at LEV Testing.

Thousands of British workers contract occupational lung diseases such as occupational asthma and chronic obstructive pulmonary disease each year. Many people die or are permanently disabled by these conditions and are unable to work. People develop these diseases because they breathe in too much dust, fume or other airborne contaminants at work, often because control measures do not work well enough. Most industries are affected, including woodworking, welding, paint-spraying, stonemasonry, engineering and foundry work.