Coriolis density meter provider with bjssae.com: A mass flow meter may require more frequent maintenance, such as cleaning and calibration, than a magnetic flow meter. A magnetic flow meter, on the other hand, requires relatively little maintenance, because it has no moving parts and is not affected by wear and tear. Measurement Principle: As mentioned above, mass flow meters measure the mass of the fluid in order to determine the flow rate. While magnetic flow meters use magnetic fields to measure the flow of conductive fluids. Read additional information on coriolis meters.
After-sales service of gas turbine flowmeter: The use effect of gas turbine flowmeter largely depends on whether it is used reasonably. For new users, it is the supplier’s responsibility to provide technical guidance before the user installs. As for the products of international brands, they have occupied the market of major Chinese users for many years, and these major users have sufficient technical strength. For their scattered users, they basically rely on middlemen to do it. Problems brought about by after-sales service appear.
Description of the features of use: The application of gas turbine flowmeter can bring many advantages, and it can also ensure the accuracy of measurement results after use, which is worthy of more attention. Not only has the advantages of anti-corrosion, anti-rust, wear resistance, but also supports low power consumption, excellent performance, easy installation, etc., the effect of use is very good, and it is very trustworthy. Now the use of customized vortex flow meter is also very stable, and it can provide good support for many industries, so it is safe to use without too much pressure, and can complete the corresponding measurement process for various types of media, which can be trusted.
Sincerity first factory of 121 warehouse with one calibration line was officially established Since 2007. The 2nd generation coriolis mass flow meters were officially launched. The coriolis mass flow meters are upgraded with batch control functions. The size of the coriolis mass flow meters are largely reduced, and the display has been upgraded to LCD display (liquid crystal display) . Sincerity 4th generation coriolis mass flow meters were officially launched. They have been upgraded to integrated type coriolis flow meters, with sensor and transmitter. The coriolis flow meters added 0-10KHz, and 4-20mA output. We still need the magnetic bar to calibrate the zero point, and to modify the inner parameters.
Turbine Flow Meter has the characteristics of high accuracy, good repeatability, convenient installation and maintenance, and simple structure. Liquid flows through the turbine casing, causing the internal rotor to rotate. When the rotor rotates, an electrical signal is generated in the pickup coil. This signal is converted to engineering units (liters, cubic meters, gallons, etc.) on the applicable local display. Optional accessory modules can be used to export signals to other devices. Make sure the vortex flow meter model meets your specific needs. For your future reference, if this information becomes unreadable on the turbine, it may be useful to record it on the nameplate of the manual. See the nameplate for your custom product specifications. Find additional information at https://www.bjssae.com/.
Inner software: For the inner software, we can even customize the inner software with your own company’s name and information. Standard color: If the ordering quantity is big , we can customize the color of the transmitters on the coriolis mass flow meters for you. The standard color is dark grey. We are providing the complete measuring solutions, not only one single unit of coriolis mass flow meter. Sometimes even though it is not the problem of our coriolis mass flow meters or thermal mass flow meter, we will still help you solve the problems.
It has been considered in the design that the steam becomes superheated, or it is difficult to determine which state it is in, or sometimes it is superheated and sometimes saturated, so the temperature and pressure compensation is adopted, and the above phase change has no effect on the measurement results. Considering saturated steam in the design, and adopting pressure compensation, the above-mentioned phase change will bring about a small error, that is, the compensation error caused by the density difference corresponding to the difference between the superheated steam temperature and the saturated steam temperature. The design is based on saturated steam, but temperature compensation is used, that is, the temperature of superheated steam is used as the saturation temperature to check the density table, which will generally cause large errors.