Quality hmi panel manufacturer: Consider the typical problems in interface design: To design any interface, we must generally consider four aspects: system response time, user help mechanism, error message handling and command mode. System response time is too long is the most complained about in the interactive system, in addition to the absolute length of the response time, the user is concerned about the difference in response time of different commands, if too much disparity in the user will be difficult to accept; user help mechanism should be integrated, to avoid the superimposed system leads to the user to help a guide and have to browse a lot of irrelevant information; error and warning information must be selected user understandable The error and warning messages must be user-friendly, accurate terminology, and should also provide some suggestions for error recovery as much as possible. In addition, the display of error information, if supplemented by auditory (ringing), visual (special color) stimulation, it is more effective; command mode is best to menu and keyboard commands coexist for the user to choose. See more information at hmi manufacturers.
The selection of PLC should be mainly considered from the PLC model, capacity, I/O module, power module, special function module, communication networking ability and other aspects. The basic principle of PLC model selection is to meet the functional requirements and ensure reliability and convenient maintenance, and strive for the best performance-price ratio. The selection should mainly consider reasonable structural type, installation method selection, corresponding functional requirements, response speed requirements, system reliability requirements, model as much as possible unified and other factors.
Order principle: That is, in accordance with the order of processing events, access to view the order (such as from the whole to a single item, from large to small, from the top to the bottom, etc.) and control processes, such as the design of monitoring management and human-machine dialogue interface and its secondary interface. Functional principle: That is, according to the specific functional requirements of the object application environment and occasions, various subsystem control types, parallel processing requirements of the same interface of different management objects and simultaneous requirements of multiple dialogues, etc., the human-computer interaction interface is designed with multi-level menus, hierarchical prompt messages and multiple dialogues, so that users can easily distinguish and master the usage rules and characteristics of the interactive interface and improve its user friendliness and ease of operation.
Wuxi Mochuan Drives Technology Co.,Ltd is one manufacturer and system solution company. To quickly match the high advantage competitive model through industry experience and solution to bring a high value market and a new growth point for our customers. We mainly provide Hmi Panel, Hmi Touch Screen , Plc Controller and permanent magnet motor. To explore more equipment value for equipment manufacturers and end users, improve efficiency, reduce costs, optimize management, and promote equipment manufacturers’ service transformation. Find more information on https://www.mochuan-drives.com/.
Use a multimeter to determine the test wiring according to the pins in the wiring diagram. Verify that the RS485 and RS232C wiring is correct, touch screens differ from various PLC wiring. This can be viewed by referring to Maintenance Control (help documentation for PLC and touch screen communication line connections), which is the basic method for normal troubleshooting of communication problems. Next I show you how to bypass the touch screen problem – online simulation. When communication fails, some customers will guess that there may be a problem with the touch panel interface or a problem with the interface. Online simulation means bypassing the touch screen and using the PLC to connect directly to the computer. Using our configuration software, the communication cable from the PLC itself is connected to the computer and an online simulation is carried out to see if the project can communicate. This can be done with a numerical input element or switch to see if the operation before and after closing the simulator and opening the online simulation is still present and if it prompts a direct NC (NC and previous operations not written down are not connected).
Multi-touch capacitive hmi panel is new design and very popular with the market. Why? It is similar the Apple iPone in our life. Becuase its flexible multi touch, very high transmittance, Glass+Glass, anti-scratching, no drifting, IPS full view TFT lcd, high resolution, brightness, high speed and easy flow, supporting animation formats. The color of multitouch HMI is rich and the picture displayed is more delicate. Why many people follows iPhone, just becuase it can bring the users different and beyond imagination experience. Same reasons, why this type panel hmi is very popular in European and American market, just becuase it can bring the project, equipment different experience then to obtain more high value market and to be easily competitive the competitors. Maybe a little try, but to bring a large value, so why not try.
The size range is 4.3inch, 7inch, 9.7inch, 10.1inch, 12inch and 15inch, with ethernet, RS485, RS232 and RS422 to meet different application using. If you have the requirement of HMI, it is good to description of your application and what function wanna realize, then the correct and the most suitable model will be recommended to you. Mochuan Drives offers three series of plc programmable logic controller, there are switch control and motion control with very strong power for choosing. Offering free software, demo, 36months warranty, mature solution. And one-to-one technical supporting online to fast solve the customer technical question. Supporting to take the video to solve the technical question, that is service do you need?
The reason is rs232 is suitable for communication between local devices, and its transmission distance is generally not more than 15m, and rs232 only allows one-ton-one communication. But rs485 transmission distance is from tens of meters up to 2Km, and rs485 interface allows up to 255 slave station to be connected. These are required to be designed by our engineers, with whom to communicate, how many devices to communicate, how to achieve the final function, whether to take into consider the interference problems of the field environment etc. All of the above are considered.
MochuanDrives supports industrial hmi touch panel from 4.3inch to 32inch, and supports multiple serial ports with different communication parameters to meet the needs of different projects. Provide free software and online technical one-on-one worry-free after-sales technical support. Through the setting of early warning programming, can monitor in advance whether there is a failure of the equipment in the electrical room, can effectively prevent the loss of sudden damage to equipment.
The human-machine interface is the central link in the human-machine system, mainly by the safety engineering sub-discipline safety ergonomics to study and propose solutions based on the safety engineering equipment engineering, safety management engineering and safety systems engineering to study specific solutions and measures safety ergonomics. It realizes the conversion between the internal form of information and the acceptable form for human beings.